BRHMC - COPPER XHB PAS 5305

  • MSDS: BRHMC
  • Manufacturer: SELECTRONS LTD
  • Product Name: COPPER XHB PAS 5305
  • National Stock Number: 6810-00N038800
Product Identification

Product ID:COPPER XHB PAS 5305
MSDS Date:02/28/1990
FSC:6810
NIIN:00N038800
MSDS Number: BRHMC

Responsible Party
SELECTRONS LTD
137 MATTATUCK HEIGHTS RD
WATERBURY, CT 06725-0115
US

Emergency Phone: 203-755-9900

Info Phone: 203-755-9900

Cage: 13929

Contractor
SELECTRONS LTD
115 WATERBURY, CT 06725-0115 US

Telephone: 203-755-9900

Cage: 13929

Ingredients

NON HAZARDOUS INGREDIENTS (&/OR WATER)

Fraction By Weight: <59%


1); (COPPER AS COPPER SULFATE)

CAS: 7758-98-7

RTECS: GL8800000

Fraction By Weight: <21%

OSHA PEL 1 MG/M3 DUST;0.1FUME

ACGIH TLV: 1 MG/M3 DUST;0.2FUME

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


1,2-ETHANEDIAMINE; (ETHYLENEDIAMINE) (SARA III)

CAS: 107-15-3

RTECS: KH8575000

Fraction By Weight: <20%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM,S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:ETHYLENEDIAMINE VAPORS MAY CAUSE
IRRITATION OF THE EYES, NOSE, AND THROAT. CAN CAUSE BLISTERING OF
THE SKIN AND POSSIBLE SKIN DAMAGE. CHRONIC:MAY CAUSE DERMATITIS
OVER PROLONGED PERIOD OF TIME. ALLERGIC REACTION CAN OCCUR.
IRRITATIONAND SENSITIZATION TO THIS MATERIAL MAY BE EVIDENT.
REPEATED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EXPOSURE TO THIS MATERIAL WITHOUT THE
PROPER SAFETY PRECAUTIONS MAY CAUSE LIVER, KIDNEY AND LUNG DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:MOVE TO FRESH AIR. SKIN:FLUSH WITH COLD WATER. IF
IRRITATION DEVELOPS AND/OR PERSISTS, CALL MD. EYE:FLUSH WITH COLD
WATER FOR AT LEAST 15 MINUTES. CALL MD. INGEST:GIVE LARGE
QUANTITIES OF WATER AND INDUCE VOMITING. CALL MD IMMEDIATELY. A
PHYSICIAN SHOULD BE CONTACTED IF ANYONE DEVELOPS SYMPTOMS OF
OVEREXPOSURE TO ETHYLENEDIAMINE.

Fire Fighting

Extinguishing Media:NO RESTRICTIONS. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DECOMPOSITION PRODUCTS CAN BE TOXIC
(AMINES, CARBON MONOXIDE, AMMONIA).

Accidental Release

Spill Release Procedures:ABSORB WITH AN INERT MATERIAL AND REMOVE TO A
DISPOSAL AREA IF APPLICABLE. VENTILATE AREA WELL. CANNOT BE FLUSHED
TO ANY SEWER OR DRAIN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PROPER TRAINING SHOULD BE GIVEN TO
PERSONNEL HANDLING THIS MATERIAL.
Other Precautions:IF CLOTHING SHOULD BECOME SPLASHED OR CONTAMINATED
WITH THIS PRODUCT, IT SHOULD BE DRENCHED WITH WATER AND NOT WORN
AGAIN UNTIL LAUNDERED.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED DUST AND MIST RESPIRATOR.
3M# 8710, NIOSH APPROVED.
Ventilation:LOCAL EXHAUST:ADEQUATE EXHAUST.
Protective Gloves:IMPERVIOUS RUBBER.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:SAFETY SHOWER AND EYE BATH. ANY OTHER
EQUIPMENT SO AS TO NOT SPLASH ON SKIN.
Work Hygienic Practices:EATING & SMOKING SHOULD NOT BE PERMITTED IN
AREAS WHERE ETHYLENEDIAMINE IS HANDLED/STORED.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.145 (H*2O=1)
pH:8.8
Solubility in Water:COMPLETE
Appearance and Odor:PURPLO COLORED SOLUTION--SLIGHT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS, OXIDIZERS AND CHLORINATED COMPOUNDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF NITROGEN AND CARBON MONOXIDE
MAY BE RELEASED IN A FIRE.

Disposal

Waste Disposal Methods:MUST BE DISPOSED OF IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.